ComicBooks.com Register / Loginit's free!

Penny Dreadfuls, 1897 · page 27 of 316

Penny Blood: Serial Sensation and Working-Class Entertainment — page 27: what you’re looking at

📖 Open the full issue in the page-flip reader →
Penny Blood: Serial Sensation and Working-Class Entertainment — page 27: Penny Dreadfuls, 1897

A restored page from Penny Dreadfuls, 1897. Page through the whole issue in the reader above.

📄 Transcribed text from this page (OCR, searchable)

Machine-transcribed from the original scan — historical spelling and the odd misread are preserved.

ro ON UNDERGROUND TEMPERATURE. [cu. 1. Water SurfaceTemp. Being at Being at the Depth Temp. R. Temp. R. shutoff, 7°18. Abso- therate Absolute rateof in Water Water not consequent lute Increase of1°R. Increase ——A———, feet. shutoff. shutoff alteration ateachdepth per No. atdepths. 19R 1° F. of Temp. in Ool. : of feet. per ft. per ft. 15 9°40 10°35 —~ 0°95 — — — — — 80 9°56° 10°20 — 0°64 — — — — _ 50 9°86 10°40 — 0°54 — — — — — 100 10°16 12°30 —2°14 2°98 33 — — — 3800 14°60 13°52 +1:°08 4°44 45 . — — — 400 14°80 14°30 ~- +0°50 0°20 500 — — —_ 500 15°16 14°68 + 0°48 0°36 277 — — — 700 8 17°06 16°08 +0°98 1°90 105 —_ — — 900 18°50 17°18 +1°32 0°44 455 — — — 1100 *19°90 19°08 + 0°82 1°40 148 11°72 94 42 1300 §=21°10 20°38 +0°72 1°20 166 — — te 1500 22°80 22°08 +0°72 1°70 118 — — — 1700 24:10 22°90 +1°20 1°30 154 — — — 1900 25°90 24°80 +1-10 1-80 111 — — — 2100 *27-70 2680 +090 180 111 £49780 128 ~# 57 2300 28°50 28°10 + 0°40 0°80 250 — —_— —_ 2500 29°70 29°50 + 0°20 1°20 166 ~— — — 2700 30°50 80°30 + 0°20 0°80 250 2°80 214 95 2900 — 31°60 — — — — fT — 3100 — 82°70 — — — — — — 8300 — 33°60 — — — — — — 3390 36°15 34°10 +205 5°65 122 — — —_ 3500 — 34°70 — — — — —= — 8700 —_ 85°80 — _ — — _— —_ 3900 — 86°60 — — — —. — — 4042 38°25 38°10 +0°15 2°10 810 7°75 212 95 In the above table the first column gives the depths in Prussian feet, at which the observations of temperature were made. The second column gives the temperatures observed at the respective depths when the convection currents were stopped by the use of the geo-thermometer. The third column gives the temperature of the water in the bore-hole when the convection currents were allowed to circulate. The fourth column gives the alteration of temperature at each depth which arose from stopping the convection currents— minus-when the temperature fell, plus when it rose. The fifth column gives the increase of temperature at each depth over that at the previous one, as taken from the second column. The sixth column gives the rate of increase at each depth, measured by the number of feet which it would be required to descend to gain an increase of 1 degree Réaumur, > commiclsoolkks (CO)